Kit Specifications

Complete technical parameters, performance metrics, and compatibility information for the Metabolon Verus™ Metabolomics Profiling Kit.

kits reagents

Kit Specifications

Complete technical parameters, performance metrics, and compatibility information for the Metabolon Verus™ Metabolomics Profiling Kit.

kits reagents

What’s in the Kit

Kit Format

Plate format 96-well plate
Sample wells per plate 84 wells
QC wells per plate 12 (8 Kit QC + 4 blanks)
Minimum project size 15 samples
Maximum project size 1,512 samples / 18 plates
Multi-project per plate Supported
Supported sample types Plasma (EDTA), Serum, Urine
More to follow

Reagents and Standards

Extraction method All extraction protocols for each matrix provided (includes recovery standards)
Reconstitution solution Contains 11 standards for each mode
High-molecular weight internal standard Included
Shipping Room temperature
Storage 4° C
Automation compatible Yes

Instrument Requirements

LC platform Waters Acquity I-Class UPLC
Thermo Vanquish Flex or Horizon
Mass spec platform Thermo Scientific Orbitraps
  • Tribrids (IDX/IQX)
  • Orbitrap Exploris series (120/240/480)
  • Q Exactive (Plus and UHMR)
More instruments to follow
Software required Xcalibur 4.2 or higher Freestyle 1.8 or higher Tune Software 2.11 or higher
Analysis platform Integrated Bioinformatics Platform (web-based)
Column (not included) Waters BEH C18 (2.1 × 100 mm, 1.7 µm) column is required for this kit (not included)

What’s in the Kit

Kit Format

Plate format 96-well plate
Sample wells per plate 84 wells
QC wells per plate 12 (8 Kit QC + 4 blanks)
Minimum project size 15 samples
Maximum project size 1,512 samples / 18 plates
Multi-project per plate Supported
Supported sample types Plasma (EDTA), Serum, Urine
More to follow

Reagents and Standards

Extraction method All extraction protocols for each matrix provided (includes recovery standards)
Reconstitution solution Contains 11 standards for each mode
High-molecular weight internal standard Included
Shipping Room temperature
Storage 4° C
Automation compatible Yes

Instrument Requirements

LC platform Waters Acquity I-Class UPLC
Thermo Vanquish Flex or Horizon
Mass spec platform Thermo Scientific Orbitraps
  • Tribrids (IDX/IQX)
  • Orbitrap Exploris series (120/240/480)
  • Q Exactive (Plus and UHMR)
More instruments to follow
Software required Xcalibur 4.2 or higher Freestyle 1.8 or higher Tune Software 2.11 or higher
Analysis platform Integrated Bioinformatics Platform (web-based)
Column (not included) Waters BEH C18 (2.1 × 100 mm, 1.7 µm) column is required for this kit (not included)

Coverage, Performance and Quality

Coverage and Performance
Quality and Workflow

Metabolite Coverage Parameters

Parameter Specification Status
Metabolite search list ~1,500 metabolites Validated *
Plasma readout > 700 metabolites Validated *
Urine readout > 700 metabolites Validated *
Biological sub-pathways covered 100+ pathways searched
80+ pathways detected
Validated *
Identification level 80% Level 1, 20% Level 2 Library-confirmed
Confidence Score Lenses Tailor coverage and accuracy Unique to Metabolon

* Tested across six independent laboratories

QA/QC and Analytical Performance

The QA/QC framework begins with a System Suitability Test (SST), which confirms instrument readiness prior to sample processing. This encompasses verification of extraction solvent composition, column configuration, instrument calibration, and correct method file setup. Following plate acquisition, a Plate QC report is generated that evaluates run quality across key parameters including retention time deviation, instrument sensitivity, and mass accuracy.

QC Measure Specification Metric
System Suitability Test (SST) Pre-extracted pooled human plasma Results in ~30 min
Plate QC (PQC) Lyophilized plasma co-extracted with samples Results in ~2 hours
Internal standards
(positive and negative mode)
11 per mode; retention, peak shape, ionization monitoring < 10% RSD
Workflow Specification Time
Hands-on time Include instrument setup, samples extraction and SST/PQC review 10 hours
Instrument time Positive ionization 24hrs
Negative ionization 24hrs
48 hours
Full workflow From sample extraction to data insight 5 days

* Tested across six independent laboratories

Coverage, Performance and Quality

Coverage and Performance
Quality and Workflow

Metabolite Coverage Parameters

Parameter Specification Status
Metabolite search list ~1,500 metabolites Validated *
Plasma readout > 700 metabolites Validated *
Urine readout > 700 metabolites Validated *
Biological sub-pathways covered 100+ pathways searched
80+ pathways detected
Validated *
Identification level 80% Level 1, 20% Level 2 Library-confirmed
Confidence Score Lenses Tailor coverage and accuracy Unique to Metabolon

* Tested across six independent laboratories

QA/QC and Analytical Performance

The QA/QC framework begins with a System Suitability Test (SST), which confirms instrument readiness prior to sample processing. This encompasses verification of extraction solvent composition, column configuration, instrument calibration, and correct method file setup. Following plate acquisition, a Plate QC report is generated that evaluates run quality across key parameters including retention time deviation, instrument sensitivity, and mass accuracy.

QC Measure Specification Metric
System Suitability Test (SST) Pre-extracted pooled human plasma Results in ~30 min
Plate QC (PQC) Lyophilized plasma co-extracted with samples Results in ~2 hours
Internal standards
(positive and negative mode)
11 per mode; retention, peak shape, ionization monitoring < 10% RSD
Workflow Specification Time
Hands-on time Include instrument setup, samples extraction and SST/PQC review 10 hours
Instrument time Positive ionization 24hrs
Negative ionization 24hrs
48 hours
Full workflow From sample extraction to data insight 5 days

* Tested across six independent laboratories

Need more information about
the Metabolon Verus™ Kit?

Need more information about
the Metabolon Verus™ Kit?

Instrument Requirements

LC platform Waters Acquity I-Class UPLC
Thermo Vanquish Flex or Horizon
Mass spec platform Thermo Scientific Orbitraps
  • Tribrids (IDX/IQX)
  • Orbitrap Exploris series (120/240/480)
  • Q Exactive (Plus and UHMR)
More instruments to follow
Software required Xcalibur 4.2 or higher Freestyle 1.8 or higher Tune Software 2.11 or higher
Column (not included) Waters BEH C18 (2.1 × 100 mm, 1.7 µm) column is required for this kit (not included)